We use cookies to make your experience better. Read more
PH5SAN5 R454B 1 Stage Heat Pump
This unit has been designed utilizing non-ozone depleting and low global warming potential R-454B refrigerant.
Heat pumps with R-454B refrigerant provide a collection of features unmatched by any other family of equipment.
Industry leading Features / Benefits
Efficiency
14.3 - 16.0 SEER2 / 10.0 - 12.5 EER2 / 7.5 - 7.8 HSPF2 (depending on unit size and indoor combination installed)
Indoor air quality accessories available
Comfort
System supports programmable or standard thermostat controls
Sound
Sound levels as low as 70 dBA
Reliability
Non-ozone depleting and low global warming potential R-454B refrigerant
Scroll compressor
Internal pressure relief valve
Internal thermal overload
Loss of charge switch
Filter drier
Balanced refrigeration system for maximum reliability
Durability
Protection Package:
Solid, durable sheet metal construction
Dense wire coil guard
Applications
Long-line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.)
Low ambient cooling (down to 0°F/-17.8°C) with approved low ambient accessory kits
Limited Warranty
5-year parts limited warranty (including compressor and coil)
10-year parts limited warranty (including compressor and coil) with timely registration*
– Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration.
* Applies to original purchaser/homeowner and not available to subsequent owners except in jurisdictions where applicable laws dictate otherwise.
See warranty certificate for complete details and restrictions.
Prop 65
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov
FJ5 Comfort Puron Advance VS Air Handler R454B Refrigerant
FJ5 AIR HANDLER TECHNOLOGY AT ITS FINEST
The FJ5 fan coil has the proven technology of Carrier fan coil units with Puron Advance refrigerant as well as vertical and horizontal applications. The design features contoured condensate pans with rugged drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life, features homeowners appreciate.
Standard features include grooved tubing and louvered fins. Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners. Units come with solid state fan controls, 1-inch (25mm) thick insulation with R-value of 4.2, multi-speed motors, and fully-wettable coils. Units can accommodate factory- and/or field-installed heaters from 3 to 30 kW. Assembled at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at 0.5 inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard.
The FJ5 fan coil design is loaded with popular features. These fan coils utilize the latest in electronic commutation motor (ECM) technology through the use of high efficiency, multi-tap ECM motors allowing reliable air delivery with increased static pressure. It comes in a pre-painted (taupe metallic) galvanized steel casing. The unit is shipped with a Puron Advance refrigerant TXV (sizes 18–60).
STANDARD FEATURES
• Refrigerant leak detection dissipation system for added safety
• Multi-tap ECM (electronic commutating motor) motors – all sizes.
• Integrated motor controls, with 90-sec off TDR function, have
replaced integrated circuit board.
• Five available speed tags to meet a wide range of applications.
• Large, grooved tube, louvered fin coils.
• Efficient, quiet, time-tested blower housings and diffusers.
• Sturdy, drainable condensate pans.
• Construction innovations designed to prevent cabinet sweating.
• Tested for condensate disposal in much tougher conditions than Air
Conditioning and Refrigeration Institute requirements.
• Super-thick R-4.2 insulation with vapor barrier.
• Pre-painted galvanized steel cabinet (taupe metallic).
• Design meets stringent regulations for cabinet air leakage of less than
2% when tested at 0.5 inches W.C., and less than 1.4% at 0.5 inches
W.C. when tested in accordance with ASHRAE 193 standard.
• Installation-flexible, multipoise units.
• 2-piece modular design available for 42 thru 60 sizes. Facilitates attic
and crawlspace installations..
• Horizontal hanging provisions on cabinet.
• Newly improved filter rack area filter door insulation added for
improved air seal. No tools required to access filter.
• Factory-installed heater packages available on select models.
(5 through 15 kW).
• 3 through 30 kW accessory heaters - field installed.
• Easy plug-in provisions for heater installation.
• Entry options for high and low voltage wiring hook-up.
• Leak-preventing sweat connections.
• Factory installed thermostatic expansion valve, TXV, on all coils.
• Designed for manufactured housing applications.
WARRANTY
• Default 5-year parts limited warranty:
– 10-year parts limited warranty with timely registration*.
Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration.
* Applies to original purchaser/homeowner and not available to subsequent owners, except in jurisdictions where laws dictate otherwise.
See Warranty certificate for complete details and restrictions.
Brand/ Manufacturer | Payne |
---|---|
Model # | PH5SAN548 FJ5ANXC48L |
System Type | Cooling with Heat Pump |
Product Series | PH5SA 15 1Stg HP R454B |
Tons | 4 |
BTU | 47000 Cooling at 95F| 47500 Heating at 47F| 29800 Heatig at 17F| 23600 Heating at 5F |
Nominal SEER | 15 SEER |
System SEER | 15 SEER |
Rated SEER | 15 |
Rated EER | 12 |
HSPF Rating | NA |
Refrigerant | R-454B |
Install Position | FJ5 Multi-Position R454B |
AFUE % | N/A |
Pad Size | 36x36x3 |
Suction Line Size | 7/8" |
Liquid Line Size | 3/8" |