Bryant® Preferred™ - 3 Ton 16 SEER Residential 2-Stage AC System w/Preferred™ 96% 1 Stage, Multi speed ECM Gas Furnace(Upflow/Downflow 127ANA036-CNPVP3717AL-925SA48080E17)

SKU: 10415576

SRP: $7,212.00

OUR PRICE

Regular Price: $5,770.00

Special Price: $5,193.00

In stock

Add Items to Cart

Free Shipping in the Continental US!/

HERE IS WHAT YOU GET:


127ANA036-CNPVP3717AL-925SA48080E17
Some Items are Limited Quantities- Please Call for Availability


 




Bryant® Preferred™ - 3 Ton 16 SEER Residential 2-Stage AC System w/Preferred™ 96% 1 Stage, Multi speed ECM Gas Furnace(Upflow/Downflow 127ANA036-CNPVP3717AL-925SA48080E17)

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Be the first to review this product

127ANA Bryant® Preferred™ - Residential 2-Stage Air Conditioner Condensing Unit

Bryant® Air Conditioners with Puron® refrigerant provide a collection of features unmatched by any other family of equipment. The 127A has been designed utilizing Bryant’s Puron® refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer.

This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. Refer to the combination ratings in the Product Data for system combinations that meet Energy Star® guidelines.

NOTE: Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information.

FEATURES / BENEFITS

Efficiency

    14.0 - 18 SEER / 11.5 - 13.8 EER
    Microtube Technology™ refrigeration system
    Indoor air quality accessories available

Sound

    Sound level as low as 73 dBA

Comfort
System supports Thermidistat™ or standard 2-stage thermostat controls

Reliability

    Puron® refrigerant - environmentally sound, won’t deplete the ozone layer and low lifetime service cost.
    Front-seating service valves
    2-stage scroll compressor
    Internal pressure relief valve
    Internal thermal overload
    Low pressure switch
    High pressure switch
    Filter drier
    Balanced refrigeration system for maximum reliability

Durability
DuraGuard Plus™ protection package:

    Solid, Durable sheet metal construction
    Steel louver coil guard
    Baked-on, complete outer coverage, powder paint

Applications

    Long-line - up to 250 feet (76.2 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.)


Bryant Preferred 925SA 96% AFUE ECM Gas Furnace

RELIABLE, EFFICIENT START UP - The Plus 80x™ gas furnace uses hot surface ignition to ensure reliable start up every time your system calls for heating.

    RESPONSIVE COMFORT CONTROL - Our sophisticated furnace control answers the call for comfort with responsive, reliable system control from startup to shutdown. This component is also the key to Fan On Plus™ technology, Bryant's adjustable constant fan function (requires compatible thermostat).

    ENERGY-SAVING BLOWER - The electronically controlled, programmed blower provides airflow optimized for your home's needs. The variable speed blower motor offers higher efficiency performance than most standard, PSC-type motors.

    IMPROVED INDOOR AIR QUALITY - Our standard air cleaner cabinet accessory helps enhance the quality of your indoor air. When installed as a part of your system, this cabinet allows the easy and convenient addition of a Bryant® high-efficiency air filter (filter sold separately).

    GAS EFFICIENCY - Our inducer fan draws the precise amount of air needed through the system's heat exchanger for enhanced heating performance and gas efficiency.

    ADDED SAFETY - Our exclusive Blocked Vent Safeguard™ protection means this furnace shuts down if a common vent is obstructed, keeping potentially harmful flue gases away from your living areas.


CARRIER/BRYANT CNPVP (T) Transition Type Evaporator Coil

This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are available for use in Puron®, R-410A refrigerant and R-22 systems. Both designs have a painted case and come with factory-installed thermostatic expansion valves (TXV). The coils are offered in different width configurations for use in multiple installation applications. Additionally, they are offered in a transition configuration, a design which simplifies making field-supplied transition duct configurations. Easy maintenance is provided as the coil slides out of the cabinet after removing the access door and service panel. The coils are available in sizes 018 through 061 (1-1/2 to 5 tons).
Transition coil models CNPVT are designed for use with one size smaller width furnaces without field modifications.
Aluminum Coils - "L" models are built with aluminum hairpins, designed to resist both general pitting corrosion and excessive indoor Formicary Corrosion. (Formicary Corrosion is an industry phenomenon.)

STANDARD FEATURES
Water Management - These coil designs do an excellent job of water management. The coils are designed to avoid water blow-off into the ducts by directing condensate away from the fins and into the drain pan.
Durable Condensate Pan - Each coil is equipped with a corrosion-resistant condensate drain pan. The condensate drain pan is designed with a slope to help ensure proper drainage, improved moisture removal, and home comfort.
Compact Design - Unique design offers as much as 2 to 4 in. (51 to 102 mm) less in height to aid in tight installations.
Brass Inserts - Every condensate pan features two 3/4 in. female threaded brass insert connections. The unique brass inserts provide for a leak-free condensate line connection to prevent water damage.
Refrigerant Connections - The coils are provided with proven sweat-connections for leak-free operation maintaining system reliability.
Burst Pressures - These coils meet or exceed burst pressure of 2100 psi which is at least three to five times the pressure they will see in actual application.
Thermostatic Expansion Valves (TXV) - All Carrier coils have refrigerant-specific factory-installed TXVs.
Teflon Ring - The ring, installed inside the liquid line connection at the TXV, is the best option for preventing refrigerant leaks and future service calls. Teflon works with both Puron, R-410A, the environmentally friendly refrigerant and R-22 refrigerants.
Protective Tube Sheets - Protect the durable copper tubing from being damaged during the manufacturing and installation process.

Brand Bryant
Model 127ANA036-CNPVP3717AL-925SA48080E17
System Type Cooling with Gas Heat
Product Series Preferred
Tons 3
BTU 36000
Nominal SEER 17 SEER
System SEER 16 SEER
Rated SEER 16.00
Rated EER 13.00
HSPF Rating NA
Refrigerant R-410A
Furnace/ Air Handler/ Coil Install Position Upflow/Downflow
AFUE % 96%
Pad Size 36x36x3
Suction Line Size 7/8
Liquid Line Size 3/8